Medical Waste Incinerator for Coronavirus Disease(COVID-19)

* Full range incinerator with Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. * Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. * System solutions for medical waste environmental. * High burnning rate, from 5kgs to 1000kgs per hour. *…

Read More

Incinerator USA Pharmaceutical

Basic Info. Model NO.:incinerator supplier in saudi arabia Export Markets:Global Product Description Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per hour, cremation equipment…

Read More

MEDICAL WASTE INCINERATOR 30-40 Kg/ Hour Solid Waste

Combustion Chamber:  · Horizontal cylindrical design  · Inner surface carried out with first-rate refractory material, high temperature proof,  · Combustion chamber volume; 5,3 approximately.  · 1 No. loading door set on the frontal edge of the burning chamber, having a whole section  crossing, suitable to load the Hospital waste material and to unload the ashes.  · Burner capacity (under full power) 30-40 Kg/ Hour approximately  · Operating Temperature: 700-900 cXC or better  · Standard Color: Black  HICLOVER YD30(PLC) 30-50 kg/hour 60kg/feeding PLC Automatic 360L(0.36M3) 100x60x60cm 200L Yes Manual 220V 2P 0.5Kw Italy Brand   Mobile: +86-138139 31455(WhatsApp) Website: www.chinaincinerator.net   Email:     sales@chinaincinerator.net        Email:    hicloversales@gmail.com    

Read More

Tiny Lightweight Medical Burner 1500kgs per collection

HICLOVER – Medical Environmental  Model YD-30 (Custom Edition) Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 kg/hour Gas Consumption…

Read More

Incinerator with 1 or 3 section type wet scrubber

Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour…

Read More

STRONG WASTE BURNER

Main room — Consists of a monolithic high grade refractory concrete with high grade insulation backing,. Implementing a refractory hearth or equal for continuous ash removal. Secondary Chamber — Consists of high density, low thermal mass refractory ceramic fiber with an innovative low emissivity protective coating. SOLID WASTE INCINERATOR    Feeding Capacity:    200 to 220 Kg….

Read More

Incinerator Parts Mineral Insulated Thermo couple Detector K-Type 300SS

Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core  HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.chinaincinerator.net  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   smart

Read More

small scale municipal solid waste inceneration technologies

small scale municipal solid waste inceneration technologies including key  point is high temerature combustion. the chamber made with heavy duty refractory material,   we fix oil or gas burner to direct fire and auto control the system.    HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.   Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)   What do hospitals do with human waste? When the medical waste is removed from facilities, it is then disposed of in a manner that is safe for the environment. In the past, medical waste would simply be sent to a landfill for disposal. Now a days, it is sterilized and recycled before heading to a special sanitary landfill. What are the 4 major types of medical waste? There are generally 4 different kinds of medical waste: infectious, hazardous, radioactive, and general.   Nanjing Clover Medical Technology Co.,Ltd. materials not recommended for incineration incinerator bin ram price of an incinerator waste management companies in lusaka incinerator for sale garden waste incinerator medical waste disposal pdf incenetor incinerator bin Items/Model…

Read More

Wuhan virus: China mobilises medical groups to fight new coronavirus

News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus  WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak, as the country reported 830 confirmed cases of pneumonia, caused by the virus and 25 deaths by the end of Thursday (Jan 23). By Thursday midnight, Hubei Province in central China reported 549 cumulative confirmed…

Read More

Burners

shed between 5000-10000 pound per hour.Mostly waste from petroleum storage tanks. Building and construction, installment and 6 months upkeep expense including specifications.CMSD for Double Chamber Rotating Klin Kind Incinerator (1st Chamber temperatur less than 850 level centrigrade & & 2nd Chamber Temperature Level less than 1200 c with exhaust pipeline 100 meter long with discharge…

Read More

Tiny array scientific waste burner

Medical Burner, 24 kg/hr. 0.016. Residential trash Hazardous waste Heater entrance. 0.065 NOX. Heater portal. Heating unit entry. Gas. Additionally eruptive as well as fireproof products not acknowledged Refine way. Oil. Blower. . Coal oil, diesel oil Temperature degree inside 1000 W Applied For. ( mg/m3 ). Medical pharmaceutical along with pleasant fluids Wastes 2…

Read More

Containerized Incinerators

Model CA50 Feed Capacity Average 60 kgs per feed Burning Rate Average 70 kgs per hour Burning Time per Feed 1 hour Voltage 220V Power 0.7Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) Average 18 Kgs/Hour Internal Dimensions 100x80x70cm (Primary Chamber) External Dimensions 230 x 130 x 155cm (main body)…

Read More

Medical Waste Incinerator Capacity Average 100kgs per hour

Temperature Display & PLC Control Case Main Combustion Chamber Incinerator Main Body ***Primary Combustion Chamber Italy Oil/Gas Burner ***Chimney:10.0Meters ***Secondary Combustion Chamber***Smoke Filter Chamber ***Italy oil/gas burner: 02 units ***Oil Tank (if oil fuel): 200Liters ***Incinerator PLC Control Case Items/Model TS100(PLC) Principle Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode…

Read More

About Us HICLOVER

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including…

Read More

Medical Waste Burner Capability Requirement 100kgs per hr

Temperature Level Show & & & & PLC Control Instance Main Burning Chamber Incinerator Text ***Primary Combustion Chamber Italy Oil/Gas Heating Unit ***Chimney:10.0Meters *** 2nd Burning Chamber *** Smoke Filter Chamber ***Italy oil/gas burner: 02 units ***Oil Tank (if oil fuel): 200Liters *** Heater PLC Control Circumstances Items/Model TS100( PLC) Principle Waste Incineration Therapy Melt Cost…

Read More

Cost to Buy a Medical Waste Incinerator

Basic Info. Model NO.:cremation equipment for sale in china Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to order  * High temperature, long life of incinerator.  * Free or minimal installation on site.  * PLC Control Plane….

Read More

Diesel/LPG/LNG burning primary combustion chamber/primary combustion incinerator

Primary combustion Burn Rate 50kg/h minimum Weight (kg), please indicate: Secondary Chamber Gas Retention Time – 2 Seconds Fuel – Diesel/LPG/LNG, please indicate Power Supply for Control Box – 220V-240V 50Hz single phase Minimum working temperature 850 °C, please indicate One year Spare Parts Package for complete maintainability Both primary and the secondary temperatures maintained…

Read More

Model TS30 oil fired waste Little incinerator 30kgs

Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30(PLC) Picture   Burn Rate Typical 20-30 kg/hour Feed Capacity Typical 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Typical 13.3…

Read More

Hot sale small waste incinerators 30kgs and 50kgs per hour”

Items/Model TS30(PLC) TS50(PLC) Burn Rate 30 kg/hour 50 kg/hour Feed Capacity 60kg 100kg Control Mode PLC PLC Combustion Chamber 330L 560L Internal Dimensions 75x75x60cm 100x80x70cm Secondary Chamber 180L 280L Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V Power 0.5Kw 0.7Kw Oil Consumption (kg/hour) 10.2–20 12.1–24 Gas Consumption (m3/hour) 9.8–20 9.9–26.1 Temperature…

Read More

Pyrolytic Twin Chamber Incinerator Small Size : Burning Rate : 30-45 kg/hr ; Optimum Loads Ability : 400 kg

Items/Model TS50( PLC) Image Principle Strong Waste Incineration Burn Price 30-45 kg/hour Control Mode PLC( Programmable Reasoning Control Heater) Burning Chamber 560L Inner Measurements 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Establishing Manual Voltage 220V Oil Consumption (kg/hour) Frequent 13.3 Gas Intake (m3/hour) *** Temperature Level Screen Digital Show Temperature Level Degree Protection…

Read More

Horizontal Solid Rubbish Incinerator

Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Key Features:  * All models with Dual combustion chamber. *according to order  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimal installation on site.  * PLC Control Plane for Intelligent operation. *according to order  *…

Read More

Little Incinerator Primary Chamber Secondary

Basic Info. Model NO.:small incinerator medical waste manufacturer Export Markets:Global Product Description Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As distinct circumscription, incinerator can be named many words as under:  Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant.  All around the world, in many countries,…

Read More

Refractory Concrete Burner

2 medical waste incinerators version YD-50, 150 kg feed capacity, 220/380 V, 50 Hz c/w 5 mtr. chimney. Will be good for comparison. Our most important byproducts are the slaughtered unwanted carcass. •             Using diesel as fuel •             Capacity 50kg per hour •             barrels substance: Refractory Concrete •             Number of chambers: 2 •             Manual feed…

Read More

Incinerator Yd-500

Product Description Model YD-500  Burning Rate  500 kgs/hour Feed Capacity 800 kgs Primary Combustion Chamber 4000 Liters Secondary Combustion Chamber 1500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 2.24Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 31–59.1 kg/hour Gas Consumption (Natural…

Read More

50 Kg Per Hour Incinerator

Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30…

Read More

dispose Medical waste IV

the incinerator can be used to dispose  Medical waste IV, used needles, used syringes, scalpels, used dressing material,personal protective equipments such as dress, gloves etc. amputated body parts, excreta from patients and other laboratory waste.incineration units that can handle a mixture of medical and hazardous wastes. The healthcare wastes include (but aren’t limited to) materials…

Read More

Wet scrubber for incinerators

having waste from production process which is having very fine/powder material with moisture of 40%. Will this machine suitable for this application. For power waste, proposal plus wet scrubber system. Optional 1 section type: Wet Cooling Spray Scrubber. Function: cooling, remove dust.   Optional 3 section type: Wet Cooling Spray Scrubber+Wet Dust Scrubber+Fog and Water Separator….

Read More

Needed Specs for Mobile Incinerator

PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING SYSTEM AUTOMATED ASH REMOVAL SYSTEM GAS SCRUBBING SYSTEM…

Read More

Required Specs for Mobile Burner

PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING SYSTEM AUTOMATED ASH REMOVAL SYSTEM GAS SCRUBBING SYSTEM…

Read More

Containerized Mobile Type Medium Unit Waste Incinerator

Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50(PLC) Picture   Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Optional Upgrade Containerized Mobile Type Incinerator ISO 20′ Full Container Combustion Chamber 560L Internal Dimensions 1000x800x700mm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/240V 50Hz 1P…

Read More

a DUCK ranch heater

Outside installment. The clinical waste incinerator will be mounted outdoors. All incinerator components will be suitable for however not restricted to outside shaded setup, including electrical motors, be resistent to corrosion, wetness and also related climate aspects. can you please forward me a few advice. An ideal Burner for Incineration of oil, plastic hazardous waste,…

Read More

Incinerator

Basic Info. Model NO.:10 kg per hour Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Items/Model TS10(PLC) Burn Rate 10 kg/hour Feed Capacity 20kg Control Mode PLC Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour)…

Read More

Containerized Mobile Incinerator Model CA50

Waste Incinerator (Containerized Mobile Burner) Ability: Average 50 kgs per hr Design CA50 Interior Dimensions 100 x 80 x 70 cm Main Item List Main Burning Chamber Additional Burning Chamber Smoke Filter Chamber Burner Control Situation Chimney:5.0 Meters *( upgrade to Stainless-steel, cost-free price) Italy oil/gas heater: 02 Components Oil Container (if oil fuel): 200Liters…

Read More

Small scale clinical waste incinerator

Toxic and Harmful wastes, Combustion supporting materials Oil Industrial wastes 35.64 small scale medical waste incinerator Prerequisites <78dB Index of let smoke and waste gas Medical Incinerator, 24 kg/hr including panel board, controls and accessories Guide Medical Incinerator, 24 kg/hr 200 beds Input Fashion Domestic garbage Chimney 0.016 800-10000C 1000-12000C Burning efficiency Gas Medical Incinerator,…

Read More

Municipal Waste Incinerator

Basic Info. Model NO.:medical waste incinerator manufacturer Export Markets:Global Product Description Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to sequence * High fever, long lifetime of incinerator.  * Free or minimal installation on site.  * PLC Control Plane. *according to order  * New Design for pet…

Read More

Tool Range Solid Waste Burner

Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150( PLC) Principle Waste Incineration Treatment Reduce Rate Average 150 kg/hour…

Read More

BIOHAZARD DISPOSAL INCINERATOR CONTAINERISED IN A 20 FT CONTAINER

TECHNICAL SPECIFICATIONS: COMBUSTION CHAMBER VOLUME (M3); 0.54 m3. SUGGESTED BATCH SIZE: 60 KG, BURN RATE: 69 KG PER HOUR, AVERAGE FUEL CONSUMPTION 13 KG PER HOUR, OPERATIONAL TEMPERATURE: 950-1320 CELSIUS, GAS RETENTION IN SECONDARY CHAMBER 0.5 SECS, WITH TEMP. MONITORING, AVERAGE ASH RESIDUE: 3%, THERMOSTATIC DEVICE: YES, 2. 50 kg/hr TECHNICAL SPECIFICATIONS: COMBUSTION CHAMBER VOLUME…

Read More

HICLOVER Medical Facility Medical Waste Burner in Stock for 2019-nCoV SARS-CoV, sars, coronavirus, Novel coronavirus

Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set…

Read More

Hazardous Waste Incinerators

Basic Info. Model NO.:furnace for incineration of animal waste Export Markets:Global Product Description Secret Features:. * Free or minimal installation on site. . 3. Neighborhood & & Sea Port & Station: Municipal Strong Waste, etc.. . * One year guarantee on burner and also parts in supply. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate…

Read More

What are the main products of incineration process

Items/Model TS800 Picture   Principle Animal Waste Incineration Treatment Burn Rate Average 300-450 kg/hour Feed Capacity Average 1200kg/feeding Control Mode Electric Control Combustion Chamber 3000Liter Internal Dimensions 300*100*100 cm Secondary Chamber *** Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) ***waste to energy plants Price Gas Consumption (m3/hour) Ave.22.8m3n/hr Temperature Monitor Digital Display Temperature Protection Yes…

Read More

50kgs per hour burner with Two chambers vendors from china

50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Variation YD-50 Burning Cost Average 50 kgs/hour Feed Ability Typical 150 kgs Primary Burning Chamber 900 Litres Additional Combustion Chamber 300 Litres Mix Burning Chamber Yes Smoke…

Read More