Mobile Small Range Medical Waste Incinerator with Cart or Wheel
Mobile Small Scale Medical Waste Incinerator with Trolley(E-Power) or Wheel Model YD-30 Picture Burning Rate average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel…
1 Ton Per Day Medical Incinerator
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Key Features: * All versions with Dual combustion chamber. *based on order * Stainless Steel chimney/stack, long lifetime. *according to order * High temperature, long lifetime of incinerator. * Free or minimal installation on site. *based on order * New Design for pet animal cremation company. …
Waste Incineration HICLOVER Model TS75
Waste Incineration HICLOVER Model TS75 Items/Model TS75( PLC) Photo Concept Waste Incineration Burn Rate Average 75 kg/hour Feed Capability Common 150kg Control Establishing PLC( Programmable Thinking Controller Burner) Burning Chamber 770L Inner Measurements 100x81x95cm Second Chamber 385L Smoke Filter Chamber Yes Feed Setting Guide Voltage 220V Power 0.7 Kw Oil Consumption (kg/hour) Common 16.9 Gas…
Waste Incineration Therapy BURNING PRICE: 100-150kgs per hr HICLOVER TS150
BURNING RATE: -100 -150 kgs per hour MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING) MAX OPERATING TEMPERATURE LEVEL: 1000-1200 oC (AFTER HEATER BURNING) SECONDARY MELTING CAPABILITY: COMPULSORY DENSITY INSULATION: 50 mm high Refractory Capacity: minutes 114mm STURDY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME: MAXIMUM 3HRS GAS TYPE: FUEL OIL (DIESEL) FUEL INTAKE…
HICLOVER Needle Incinerators-Syringe and Destroyer-Needle Destroyer
1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ). 2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk. 3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization…
Refuse Incineration Plant
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs Picture Primary Chamber (Liters) 200…
Front Load Waste Incinerator
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to order * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs…
Hospital Incinerators 50 Kg/Hr Ability
Basic Info. Model NO.:build portable small scale incinerators Product Description Pyrolytic incineration specialized is conventional waste treatment way for many years. All over the world, in most countries, people anti incinerator since the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical…
Waste Clinic Incinerator
Basic Info. Model NO.:united states animal incinerators for sale Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. A Model animal crematory burning rate from 20-400kgs per hour. Heavy duty combustion chamber and match for large animal cremation. Residency time 2.0 sec. In post combustion chamber. Virtually smoke…
Light Weight Small-Scale Medical, Mobile Optional Kind
Light Weight Small-Scale Medical, Mobile Optional Type Model YD-30 Picture Burning Rate average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3…
Containerized Mobile Kind Tool Device Waste Burner
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50( PLC) Image Idea Waste Incineration Therapy Melt Price Criterion 50-100 kg/hour Feed Capability Typical 200-300 kg/feeding Control Mode PLC( Programmable Reasoning Controller Burner) Optional Upgrade Containerized Mobile Kind Burner ISO 20′ ′ ′ ′ Complete Container Burning Chamber 560L Interior Measurements 1000x800x700mm 2nd Chamber 280L Smoke Filter Chamber Yes Feed Setting Guide…
Model TS30 oil fired waste small incinerator 30kgs
Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30(PLC) Picture Burn Rate Average 20-30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Average 13.3…
Top Feeding Door HICLOVER Waste Incinerators
▲▲Primary Combustion Chamber▲▲Secondary Combustion Chamber▲▲Smoke Filter Chamber▲▲Optional Wet Scrubber System(1 section or 3 sections)▲▲Large Feeding Door▲▲Better for Animal Waste Cremation
low-priced medical waste burner
Heap: TIMBER PALLETS. – ABIDES BY EURO/ OR US-EPA EXHAUST SPECIFICATIONS – OPERABLE BY 1 INDIVIDUAL, WITHOUT ANY TRAINING REQUIRED – GAS SCRUBBING SYSTEM – COMPUTERIZED ASH REMOVAL SYSTEM – 95% REDUCTION OF SOLID WASTE Type: Cord Supported – AUTOMATIC LOADING SYSTEM Elevation:3 Meters or even more – PROCESS AT THE VERY LEAST 1 METRIC…
Smokeless Medical Incinerator
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to order * High fever, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per…
Pet Crematory with Movable system & & Automobile. Door & Independent Position
Incinerator Model A1500, Introduction This version is big-scale pet cremation tools for enormous creatures. Construction is dual/double combustion chamber with 03 units oil/gas burner, batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). Primary & Secondary combustion chambers and included mix-combustion chamber, smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load…
Effect of biomedical waste on human health
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.chinaincinerator.net/ Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Equipment Technical Specifications Model TS30S Picture Feed Capacity 78 Liters for primary chamber Burning Rate Typical 30 kgs per hour Burning Time Each Feed 0.5 hour Voltage 220V Power 0.5Kw Fuel Diesel oil Burner Diesel Oil Burner, 2 sets Feed Mode Manual Fuel consumption (Oil) Typical 8 Kgs/Hour External Dimensions 90 x 90 x…
Waste Incineration Therapy Incinerators Avg.100kgs per hour
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc….
HICLOVER Waste Incinerator 10-500kgs/Hr.Double Combustion Chambers
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm Secondary Chamber 600L 750L 1000L 1500L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber…
large scale incinerator
Programming controls. planned method. Appropriate prepurge, ignition, postpurge, and modulation ought to be verified. A stopwatch ought to be used for confirming periods of time. ? The satisfactory operation of the fuel control solenoid valves for all requirements of operation and shutdown should be verified. ? A low voltage test ought to be run on…
medical waste heat value
18 Electrical supply required 3-phase 19 Auxiliary fuel Diesel or paraffin 20 Main burner 21 Secondary (Later ) burner 22 Kind of burners Automatic pressure jet 23 Output Primary Approx 600 000 kJ/hour 24 Output Secondary Approx 750 000kJ/hour 25 Emission control Heated refractory screen Low Speed grit arrester screen Built in 26 Paint Instance…
medical waste incinerators china
Ensure flame contact with all gases is achieved. –yes Ensure residence time is not less than two (2) seconds. –yes Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is less than 1100oC. –1000-1200 oC Ensure the oxygen content of the emitted gases…
Medical Incinerator Manufacturers in Supply all set for shipping
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.chinaincinerator.net Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless…
a pet cremator
11 Burners Fire Brick, Refractoy Block, Concrete 2 Double Burning Chamber with Integrated In Smoke Filter (Dry Scrubber) 6 220/380 Volt A/c 50 Hz. 10 Summary 1 Incinerator Kind Feed Setting Premium Quality European CE Qualified Oil Burner 8 Standard PLC Control Panel 9 an animal cremator for our organization in malaysia.currently we’re doing specific…
Solid Waste Processing
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to order * High fever, long life of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per…
00 BEDS HEALTHCARE FACILITY INCENERATOR TECHNICAL INFORMATIONS
1) Policy – – Waste disposal administration will be taken special note to prevent health center infection. – – Infections wastes shall be cared for, stored only and burned by a burner situated at hospital site. 2) Waste Disposal Plan a)Classification – – Medical wastes in healthcare facility are categorized as follows; Infections Waste Specially-controlled waste Organ,…
Dedicated Medical Waste Incinerators
Basic Info. Model NO.:double-chamber pyrolytic incinerators Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd. Nanjing Clover Medical Technology Co., Ltd.. Key Features: * All versions with Dual combustion chamber. *according to order * Stainless Steel chimney/stack, long lifetime. *according to order * High temperature, long lifetime of…
mobile incinerator china
of the year is March. Environmental temperature can be such that poor rubber and plastic materials can easily melt or deformed. Bidders must ensure all substances are going to have the ability to withstand such temperatures 4) Humidity: humidity is usually high about 65 — 90%. Electronic components must be protected to prevent the…
Regarding Hiclover Medical Enviromental
The household pet cremation equipment humanized design with movable platform, small area covers for modern-day pet cremation local business owner throughout the world. HICLOVER is growing brand for environmental protection field, and also market show most of Africa, Middle East, Southeast Asia countries as well as part of North America, Europe area. We a re…
30kgs rate 60kgs feed oil and gas burner small waste incinerator
30kgs rate 60kgs feed oil and gas burner small waste incinerator for Afghanistan Machine Working mode Oil or Gas + Power Voltage 220V Oil consumption (lit/hour) Average 13.3lit/hour/chamber Gas consumption (NG) (m3/hour) 16.0 (m3/hour) (NG) Gas consumption (LPG) (m3/hour) 11.7 (m3/hour) (LPG) Burning rate Average 30kg/hour Feed mode Manual Primary Combustion chamber 360 Liters Secondary Combustion…
crematorium manufacturers
Doors The doors shall be hinged on the right hand side and can be easily opened and closed. Incinerator will NOT incorporate automatic doors. Stack The stack shall be fabricated from pre-determined thickness stainless steel plate suitably flanged for connection. Combustion Air Blower A combustion air blower shall be of steel construction type…
Design TS30 oil ended waste tiny burner 30kgs
Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30( PLC) Picture Melt Price Average 20-30 kg/hour Feed Capacity Regular 60kg per feeding Control Establishing PLC( Programmable Thinking Controller Incinerator) Burning Chamber 330L Inner Measurements 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Establishing Manual Feeding Voltage 220V Power 0.5 Kw Oil Utilization (kg/hour)…
Process Engineering Design of Pathological Waste Incinerator
Basic Info. Model NO.:small medical waste incinerator manufacturers Export Markets:Global Product Description Technology Respond(FAQ) Q: What’s kind of waste can utilize within this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live squander. Prohibit any volatile and radiation substance, liquid waste and gas waste. Q: Incinerator Smoke Standard A: China Government Standard:…
Medical Waste Incinerator of 20 kg/hr capacity with Double burner
3 Medical Waste Incinerator of 20 kg/hr capacity with double burner.Medical Waste Incineration Systems. I’m interested to ruin about 200 kg stays. A Medical Incinerator project for Tehran municipality. Our goal for this project is to set up a plant in order to incinerate Medical waste with 50 ton/day capacity. A incinerator with 100 kg…
low-cost medical waste incinerator
Stack: WOOD PALLETS. • 95% REDUCTION OF SOLID WASTE • TEMPRATURES DURING THE COMBUTION PROCESS MUST EXCEED 1,500 °F FOR AT LEAST 1-HOUR • FIVE (5) YEAR COMPONENT WARRANTY FROM DATE OF ACCEPTANCE • AUTOMATIC LOADING SYSTEM • ABILITY TO INCINERATE WASTE PETROLEUM, OILS, AND LUBRICANTS • CAPABLE OF 24 HOURS OF CONTINUOUS USE We…
Afterburner Preheat Burner
PRIMARY CHAMBER Sturdy steel casing Top quality refractory lining and insulation Big full dimension leading tons counteracted door Avg Ash Residue Temperature level Tracking YES ANCILLARIES Running and maintenance guidebooks Saves list TRICK FEATURES – Afterburner Preheat – Incineration temperature levels over of 1300 ° C – 5mm steel covering and totally shield – Dense…
INCINERATOR DIESEL FIRED
Upkeep control proposition. Specs with a capability to melt 100kgs/Hr. Best quality air-cooled stainless steel. The chimney/stack must have a. ▪ Connect heaters to fuel supply. To bum medical waste in a clean in addition to environmentally effective cargo”. accreditation. The total construction and constructing period. The delivery. 5 Ability to support tools. the specialist….
Incenerator System
Incenerator Supply, installation and testing of medical waste incinerator with a capacity of 75 kilograms / hour, operated by LPG and including all accessories with chimney in accordance with the technical specifications and public health regulations Item 2 Incinerators room for 3 incinerators as item 3-1-1, and waste store for keeping wastes for 7 days,…
dispose Medical waste IV
that the incinerator can be made use of to do away with Clinical waste IV, used needles, used syringes, scalpels, made use of dressing product, private security gadgets such as gown, gloves etc truncated body parts, excreta from customers and also various other research laboratory waste.incineration tools that can deal with a mix of clinical…
Hotel Waste Incinerator
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Key Features: * All models with Dual combustion chamber. *based on order * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hour, up…
Stoven to Cremated Pets
Basic Info. Model NO.:used medical waste incinerator italy Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Presently, we provide different series for local customer requirements and design upgraded incinerator with our leading technology. The updated design characteristic of our assortment of incinerators make them one of the most cost effective in the world. …
BURNER SCREENING AND ALSO COMMISSIONING
The strain will be elevated gradually in addition to steadily up until the defined examination pressure is gotten to that pressure will be maintained for a period sufficient time to allow a comprehensive examination to be made to make certain that the tank is sound enough and discloses no leakages or excessive distortion. The storage…
General waste incinerator, dual chamber (primary & secondary)
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.chinaincinerator.net/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS30(PLC) Picture Burn Rate Average 30-50 kg/hour Feed Capacity Average 60kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 1.0 Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour) *** Gas Consumption…
incinerator burners
Fully automatic sequential control provided by internal Secondary chamber pre-heat Burn cycle (variable) Cool down cycle PLC system providing control of: Gas Alternatives Diesel, LPG, Natural or Bio Gas. Average Gas Consumption Diesel: 8 / 10 litres per hour Liquid Propane Gas: 6 / 8 litres per hour Natural Gas: 7 / 9 Nm3 per…
Supply, Installment and also appointing of Waste Incineration system
Page|5 – Temperature degree of second and key chamber. – All the burner parts including fuel pumps, followers, pipelines and also shutoffs can be conducted in high ambient temperature level (50OC). The bidder will give all vital information connected to the facility dimensions, room area needed for the entire system as well as all procedure…