50kgs/hr iraq general waste burner with Two burning chambers

Items/Model TS50M Picture Melt Price Average 50 kg/hour Feed Capability Average 50-150 per feeding Control Mode PLC( Programmable Reasoning Controller Incinerator) Combustion Chamber 450L Internal Measurements 75x75x80cm Added Chamber 225L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5 Kw Oil Usage (kg/hour) Average 13.3 Gas Usage (N.G, m3n/Hour) Average 16 Gas…

Read More

animal incinerator price

This Server Pack (Supplied As Part of the Machine) Constitutes Sufficient Parts to Keep the Machine Adequately For A 3 Years; the Parts from the Kit Mainly Related To Diesel Fired Burners and Are As Follows;   Thermocouple Temperature Sensor -2 Burner Blast Tubes -3 Burner Diffuser Assemblies -3 0.65 Dia: Nozzles -4   There…

Read More

Animal incinerator for pig farm Average 100 kgs per hour

Model A1500 (customer made model) Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – yes Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Optional Part) Incinerator Control Case Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) Italy oil…

Read More

little healthcare center waste incinetor

WASTE INCINERATOR –          150 KG/HR –          Compliant with EU rules, Directive 2000/76/EC –          Fuel type: Diesel –          Easy management and maintenance –          Temperatures: 850 deg C for municipal waste 1000 deg C for medical waste 1100 deg C for harmful waste containing halogenated organic substances with content of chlorine or its compounds.a incinerator with an…

Read More

medical waste management

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming in contact with the often toxic materials discarded by hospitals and other healthcare websites. Hospital waste varies from site to site and the biggest challenge is to dispose of the wide assortment…

Read More

Incinerator

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combined Water Treatment Export Markets:Global Additional Info. Trademark:clover Product Description Items Specification Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) Main Product List Double Combustion Chamber Smoke Filter Chamber PLC Mode Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel)…

Read More

Medical Waste Treatment Equipment

Basic Info. Model NO.:medical waste incinerator manufacturers in china Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. Items/Model YD-30 YD-50 YD-100 YD-150 Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000…

Read More

Waste Medical Incinerators

Product Description Nanjing Clover Medical Technology Co., Ltd.. Items/Model TS50(PLC) Picture   Burn Rate 50 kg/hour Feed Capacity 100kg Control Mode PLC Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature Monitor Yes Temperature Protection…

Read More

incinerator plant specification

1)  Electricity Supply: (a) Mains Supply: (I)  Single Stage supply; 220 — 240V, 50Hz (ii) Three Stage supply; 380 — 415V, 50Hz (iii) The power supply outlet (sockets) for single phase distribution system at the hospital is three hooks and conforms to BS1363. (b) Fluctuation: (I)  Mains fluctuation is a frequent problem, the performance should…

Read More

Small Range Medical Waste Coronovirus (Covid 19) Incinerator 30 kgs per hr Design TS30 PLC Auto Control

Items/Model TS30( PLC) Picture Burn Rate Average 30 kg/hour Feed Capability Average 60kg per feeding Control Setting PLC( Programmable Reasoning Controller Burner) Vehicle Control and also Present Combustion Chamber 330L Inner Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5 Kw Oil Consumption (kg/hour) Average 13.3 Gas…

Read More

About Medical Waste

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses. HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste. Average 20%-25% of the total waste generated by Health Care establishments is regarded as Poisonous and may create a variety of health and environmental risks if not Handled and destroyed in an appropriate manner.  Our products ensure effective, clean and hassle-free disposal of medical waste is possible.  The incineration of clinical waste including pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies, Drug Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste. ○Middle-Small Capacity(TS Model)※Main Features:— Dual Combustion Chamber— Dual Italy Burner–Burning Rate: 10-100kgs per hour–Combustion Chamber: 0.1M3-1.2M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Upgrade/Downgrade Burning Rate ○Large-Middle Capacity(YD Model)※Main Feature:–Three Combustion Chambers— Double Italy Burner–Burning Rate: 30-600kgs per hour–Combustion Chamber: 0.36M3-5.5M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner— Upgrade/Downgrade Burning Rate ● Service before and after Installation — Factory training for installation, operational and maintenance with free cost. — Online service support for setup, operational and maintenance with free cost. — Onsite installation, operational and maintenance training— Onsite service support after installation ● Spare parts supportHICLOVER offers spare parts such as:— Burners (diesel oil, LPG or natural gas)—   Element for burners— Fire ropes— Incinerator chamber maintenance stuff — Air Fan — Temperature element—   Smoke filter brick—  Control box—  Other parts  Nanjing Clover Medical Technology Co.,Ltd.. Tel:  +86-25-8461 0201    Fax: +86-25-8461 0406

Read More

50-100-150-200 Kgs per Hr Solid Waste Burner Version TS150 PLC 1570Liters Chamber

Waste Burner Design TS150 PLC, Review Construction is dual/double combustion chamber with 02 sets oil burner, batch load  incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Primary Combustion Chamber: …

Read More

What is medical waste management

Item Specification Model YD-20C Main Product List   Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters   Optional: Phone: +86-13813931455(whatsapp/wechat)Website: http://www.chinaincinerator.net/  Mobile Trailer for Incinerator Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. bio medical waste management ppt 2020 HICLOVER Incinerator/Parts Range Main Feature Medical…

Read More

Incinerator in 100 to 500kg Per Hour

Basic Info. Model NO.:incinerator furnace manufacturer Export Markets:Global Product Description Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator.  * Free or minimal installation on site.  *based on order  * New Design for pet animal cremation business.  * One…

Read More

Procedure Fire Brick Installation at Incinerator Oil and Gas

Basic Info. Model NO.:price of burner incinerator Export Markets:Global Product Description Technology Respond(FAQ)  Q: What is kind of waste can utilize within this equipment?  A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid waste and gas waste.  Q: Incinerator Smoke Standard  A: China Government Standard:…

Read More

Incenerator System

Incenerator Supply, installation and testing of medical waste incinerator with a capacity of 75 kilograms / hour, operated by LPG and including all accessories with chimney in accordance with the technical specifications and public health regulations Item 2 Incinerators room for 3 incinerators as item 3-1-1, and waste store for keeping wastes for 7 days,…

Read More

Diesel Fired Waste Incinerator

Basic Info. Type:Incinerator Export Markets:Global Additional Info. Trademark:CLOVER CHINA Product Description Nanjing Clover Medical Technology Co., Ltd.. Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs Primary…

Read More

Medical Waste Incinerator HICLOVER TS10 PLC 10kgs per hour

medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture   Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas…

Read More

medical incinerator producer

1. 9. Steel gas storage tank from black steel (capability less than 2500 litres) and will be installed at the incinerator Space. The container will be provided with all needed installations consisting of fill, vent, drain as well as overflow line, level sign and also access for evaluation and also maintenance. Degree switches over will…

Read More

Pet burners up available

Digital Waste.{ (adsbygoogle = window.adsbygoogle || []).push({});|} Utilized electric motor oils and/or mineral oils unfit for their originally implied usage. Normally motor/gear box oil (approx. 80%) contaminated by a combination of white spirit and also acetone (approx. 5%) hydraulic liquid (approx 5%) Polluted Water. Primarily numerous kinds of Acid, Paint, Varnish, White Spirit, Aromatic-Less Solvents,…

Read More

china medical incinerator

china medical incinerator Ability ? Typical Daily Max/Min January Temperature, 2-12°C. ? Disposal of both non-hazardous and hazardous waste streams (per waste inventory) Design/Specifications ? Average Daily Max/Min June Temperature, 21-39°C ? The incinerators will be installed with visual alarms to alert operations of reduced temperature in the secondary chamber diesel fuel / mains power…

Read More

pet crematorium equipment

Finally, steam to  the coat should shut off, the unloading door is to be opened Then the shaft and mixing arms are reversed to behave as unloading mechanism and should scoop the waste fragments out of the unloading door, onto a conveyor belt or directly into a waste container. The vessel should now be ready…

Read More

cytotoxic waste

Our interest is for disposing mainly cytotoxic waste, particularly out of date or out of specs cytotoxic medicines. Numerous other wastes that we would like to obtain rid of in enhancement to the cytotoxic waste consists of obsolete or out of specs psychotropic pharmaceuticals (however not constantly narcotics), sharps (needles) and also so on. it’s…

Read More

Hiclover waste burner additional components

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products…

Read More

Technical Requirements for Medical Waste Incinerator

Basic Info. Model NO.:purchase pet incinerator cremator united airlines Export Markets:Global Product Description Technology Respond(FAQ)  Q: What’s kind of waste can utilize within this equipment?  A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.  GB18484-2001.  The animal/pet combustion rate around 2/3…

Read More

Municipal Waste Incinerator

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Application Scope:  1. Company License No.,: 320105000138343  Taxation Certificate No.: 320105571573734  Export Business Certificate No.: 3201571573734  Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg…

Read More

Medical Waste Burner HICLOVER TS10 PLC 10kgs per human resources

medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10( PLC) Picture Melt Price Regular 10 kg/hour Feed Capability Requirement 20kg/feeding Control Mode Programmable Reasoning Controller( PLC) Panel Combustion Chamber 100L Indoor Dimensions 50x50x40cm 2nd Chamber 50L Smoke Filter Chamber Yes Feed Setting Handbook Voltage 220V Power 0.5 Kw Oil Utilization (kg/hour) standard…

Read More

mobile burner

Petrol: diesel Consumption: 8-10liter/hour Capacity: to cremate (carrion and spoils) 350-400kg/hour Temperature: 900-1350?C Operation temperature: -30~40?C Incinerator weight: 1800-2000 kg Volume: 0.70-0.80m/cube Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) A heater stands for a whole service to the problem of disposal of clinical facility waste types. The liquid gas is petrol. The burner ought to meet the setup…

Read More

tiny range incinerator

? Refractory concrete:. Density: ≥ 100 mm. Nature: 42 percent of Al203? Insulate in fibrous panels: Thickness: ≥ 75 mm Character: Magnesium silicate. ? Burner of illumination of waste, with fuel, traditional mono-bloc spreading directing plunging fire, illumination and also safety and security of electronic ignition, irreversible ventilation, Burning chamber should harm the pollutant thing…

Read More

tiny range burner

? Refractory concrete:. Density: ≥ 100 mm. Nature: 42 percent of Al203? Insulate in fibrous panels: Thickness: ≥ 75 mm Nature: Calcium silicate. ? Burner of illumination of waste, with gas, conventional mono-bloc spreading directing plunging fire, illumination and also safety and security of digital ignition, irreversible ventilation, A control box ensuring that the total…

Read More

Waste Incinerators From Chinawaste, Incinerators

Product Description Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As different circumscription, incinerator can be named many words as under:  Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant.  All over the world, in many countries, people anti incinerator since the incinerator will create a large…

Read More

MEDICAL WASTE INCINERATOR WITH CAPACITY 500Kg/h

*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc     Incinerator Items/Model HICLOVER TS500(PLC)   Burn Rate (Average) 500-600 kg/hour Feed Capacity(Average) 600kg/feeding Control Mode PLC Automatic Primary Combustion Chamber…

Read More

Treatment and disposal technologies for health care waste

Items/Model TS75 Picture   Principle Solid Waste Incineration  Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 600L Internal Dimensions 100x60x100cm Secondary Chamber 300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (L/Hour) 15-20 Natural Gas Consumption (m3n/hour) ** Temperature Monitor Digital Screen Temperature…

Read More

animal cremation

Pre-programmed PLC controlled Password activated and reversal history indication Motor starter with overload protection Automatic instantaneous stop on hard object in shredder bed Automatic heavy cutting load reversal and re-try , up to three times Control housing Nema type 12 Technical Characteristics of External SHREDDER Controls:   Chamber Dimensions(WxLxH): approx 33 c m x 38…

Read More

incinerators animal

Class 2          Industrial Incinerators Class 2A:    Commercial Incinerators for the disposal of waste that contains hazardous, possible hazardous and bio-medical waste in which the operator exceeds 100 Kg/day. Dimensions: 2.2m(l) x 1.5m(w) x 2.5m(h) Fully automatic computer multi control system. Fuel Options- Diesel and natural gas, electricity Wasted fuel- >12L/h The incinerator should burn…

Read More

laboratory incinerator

the Whole carcass of animals ( Horses, Cows, air retention for at least 2 seconds at a temperature of less than 850C, the combustion C to – 15 0C laboratory incinerator Temperature and 5% – 95 percent – of moisture conditions. Which are managed remotely by the operator. ? Fully mobile – mounted on wheeled…

Read More

incinerator manufacturer

“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must prevent the discharge of black smoke and fine dust, during the loadings. It shall have the ability to reduce the quantity of wastes by 98%. It shall have the ability to hold emission in the second burn with gas residence of not less…

Read More